首页|ALUMINUM ELECTROLYSIS TESTS WITH INERT ANODES IN KF-AlF_3-BASED ELECTROLYTES

ALUMINUM ELECTROLYSIS TESTS WITH INERT ANODES IN KF-AlF_3-BASED ELECTROLYTES

扫码查看
A low-temperature KF-AlF_3-based electrolyte was used to perform aluminum electrolysis tests in a cell fitted with aluminum bronze metal anodes and wetted cathodes. Several 100A-100h tests were performed to investigate the effect of NaF concentration in the bath, current density, and temperature on cell operation. Results indicate that larger 1000A tests are warranted.

inert anodeelectrolysislow-temperature electrolytealuminum production

Jianhong Yang、John N. Hryn、Greg K. Krumdick

展开 >

Argonne National Laboratory, Energy Systems, 9700 S. Cass Avenue, Argonne, Illinois, USA

Light Metals 2006

San Antonio,TX(US)

TMS(The Minerals, Metals & Materials Society) Annual Meeting; 20060312-16; San Antonio,TX(US)

P.421-424

2006