首页|Failure Analysis on a Buried Flowline in Elevated Temperature and Acidic Soil

Failure Analysis on a Buried Flowline in Elevated Temperature and Acidic Soil

扫码查看
A buried carbon steel gas flowline suffered from accelerated external corrosion after one-year operation。 The flowline was protected by an impressed current cathodic protection and liquid epoxy polymer coating system。 Root cause analysis revealed that coal seam oxidation under wet condition generated an aggressive acidic soil environment around the pipe。 The coating and cathodic protection system in a low pH and elevated temperature (90-110℃) environment was not able to provide adequate protection from external corrosion for this flowline。

coal seamsoil acidificationelevated temperaturecathodic protectionliquid epoxy polymer coating

Wei Chu、Muhdi Sujatmiko

展开 >

ConocoPhillips Company 239 GB, Bartlesville Technology Center Bartlesville, OK 74006, USA

ConocoPhillips Indonesia Inc. Ltd. Ratu Prabu II, 7th Floor JI. TB Simatupang Kav. 18 Jakarta, JK 12560, Indonesia

Atlanta, GA(US)

Corrosion conference and expo 2009

603-611

2009