首页|THE VIBRATION OF A HIGH-RISE BUILDING'S COLUMNS DUE TO RHYTHMIC HUMAN ACTIVITY
THE VIBRATION OF A HIGH-RISE BUILDING'S COLUMNS DUE TO RHYTHMIC HUMAN ACTIVITY
扫码查看
点击上方二维码区域,可以放大扫码查看
原文链接
NETL
Annoying floor vibrations were experienced by office personnel on an upper floor of a downtown Toronto high-rise building。 A detailed investigation was carried out to determine the source of the vibration and its path。 Investigation of the problem showed the unwanted vibration was due to rhythmic human activity at 2。6Hz, approximately six (6) to eight (8) floors above。 Detailed information will be presented on the methodology of data collection, the determination of the source of the activity and how such an activity could affect floors 6 to 8 floor below。 Information will also be provided on potential mitigation solutions for vibration at this frequency。
high-rise buildingvibrationresonance
Nicholas Sylvestre-Williams、Bob Rimrott、Jihyun Cho
展开 >
Aercoustics Engineering Ltd.
International congress on noise control engineering
Lisbon(PT)
39th international congress on noise control engineering 2010