Study on Improving Load by CCPP Electric Generating Set in Steel Plant and Application of Study Results
In order to improve the load by the CCPP electric generating set,different caloric values of coal gas were used according to different ambient temperatures.So in summer,an air cooler was used to reduce the air temperature at the inlet of an air compressor,while the water in-jection system was used to reduce the fuel temperature at the inlet of a gas turbine.After these measures were taken,the combustion temperature could be reduced and the load of the CCPP electric generating set could be increased.
CCPP electric generating setloadcaloric value of coal gasair coolerwater injection