北京口腔医学2024,Vol.32Issue(2) :102-104.DOI:10.20049/j.bjkqyx.1006-673X.2024.02.006

细针吸取活检在下颌下腺肿物诊断中的价值及误诊原因分析

The value of fine-needle aspiration biopsy in the diagnosis of submandibular gland tumors and the analysis of the causes of misdiagnosis

王振 申明明 余小蒙 高润涛
北京口腔医学2024,Vol.32Issue(2) :102-104.DOI:10.20049/j.bjkqyx.1006-673X.2024.02.006

细针吸取活检在下颌下腺肿物诊断中的价值及误诊原因分析

The value of fine-needle aspiration biopsy in the diagnosis of submandibular gland tumors and the analysis of the causes of misdiagnosis

王振 1申明明 1余小蒙 2高润涛1
扫码查看

作者信息

  • 1. 100050 北京 首都医科大学附属北京友谊医院口腔科
  • 2. 100050 北京 首都医科大学附属北京友谊医院病理科
  • 折叠

摘要

目的 探讨细针吸取活检(FNA)对下颌下腺肿物的诊断价值.方法 回顾 2013-2022 年就诊于首都医科大学附属北京友谊医院口腔科,行FNA并获得最终病理的下颌下腺肿物患者,以最终病理为金标准,计算FNA诊断各型下颌下腺肿物的准确性、灵敏度、特异性、安全性,分析误诊原因.结果 共纳入 114例患者.非肿瘤性疾病多为IgG4-RD,FNA诊断准确度为 91.2%,灵敏度 97.4%,特异性 88.2%.FNA诊断下颌下腺良性肿瘤准确度:86.8%,灵敏度:81.7%,特异度:92.6%.FNA诊断下颌下腺恶性肿瘤准确度为 93.0%,灵敏度 62.5%,特异性 98.0%.误诊原因包括 10 例取样误差及 8 例病理类型误判.结论 FNA在诊断IgG4 相关性下颌下腺炎中极具价值,在诊断下颌下腺恶性肿瘤灵敏度较低,有误诊可能,需结合患者资料进行综合考虑.

Abstract

Objective To investigate the diagnostic value of fine needle aspiration(FNA)in submandibular gland masses.Methods The patients with submandibular gland masses who received FNA and surgical biopsy were retrospectively analyzed.The accuracy,sensitivity,specificity of FNA in diagnosing various types of submandibular gland masses were calculated,and the causes of misdiagnosis were analyzed.Results A total of 114 patients were enrolled.Non-neoplastic diseases were mostly IgG4-RD.The accuracy,sensitivity and specificity of FNA in the diagnosis of submandibular gland non-neoplastic diseases were 91.2%,97.4%and 88.2%respectively.The accuracy,sensitivity and specificity of FNA in the diagnosis of submandibular gland benign tumor were 86.8%,81.7%and 92.6%respectively.The accuracy,sensitivity and specificity of FNA in the diagnosis of submandibular gland malignant tumor were 93.0%,62.5%and 98.0%respectively.The reasons for misdiagnosis included sampling miss in 10 cases and pathological misdiagnosis in 8 cases.Conclusions FNA is of great value in the diagnosis of IgG4 associated submandibular gland inflammation.The sensitivity of FNA in the diagnosis of submandibular gland malignant tumor is low,and there is the possibility of misdiagnosis.The use of FNA needs to be comprehensively considered in combination with clinical data.

关键词

细针吸取活检/下颌下腺肿瘤/IgG4相关性疾病/敏感性和特异性

Key words

Fine needle aspiration/Submandibular gland tumor/IgG4-related disease/Sensitivity and specificity

引用本文复制引用

出版年

2024
北京口腔医学
首都医科大附属北京口腔医院,北京口腔医学会

北京口腔医学

CSTPCD
影响因子:0.603
ISSN:1006-673X
参考文献量19
段落导航相关论文