微泡腔光微流传感中的传质问题研究
Transport property of analytes inside optofluidic microresonators
俞骁翀 1胡晴 1张文娇 1张维元1
作者信息
- 1. 北京师范大学物理学系,应用光学北京市重点实验室,100875,北京
- 折叠
摘要
基于微泡腔的光微流传感器件得益于其优异的光学性质,在微流检测领域具有极高的发展前景,但对于其内部的传质过程缺乏系统的分析.本文通过理论计算和有限元仿真,研究了微泡腔系统内部的微流传质对其传感性能的影响.通过系统分析待测物表面吸附响应与微流系统中毛细管与微泡腔的结构参数之间的关系,发现毛细管拉锥与微泡腔的存在确实有效增强了表面吸附速率.这为该传感器的进一步优化提供了指导.
Abstract
The extrordinary optical performance of microbubble-based optofliudic sensors is highly appreciated in the field of microfliudic detection.However,analyte transport onto the sensing surface is in want of detailed studies.Theoretical analysis and finite-element-method simulation is combined in this work,to study systematically microfluidic transport inside optofluidic sensors.Diffusion limited adsorption speed is found to be enhanced via tapered capillary and microbubbles,to further optimize those microfluidic sensors.
关键词
光微流传感/微泡腔/微流传质/对流-扩散方程/表面吸附Key words
optofluidic sensing/microbubble resonator/microfluidic transport/convection-diffusion equation/surface adsorption引用本文复制引用
基金项目
国家自然科学基金(12104059)
国家自然科学基金(62131002)
广东省基础与应用基础研究基金(2022A1515011475)
出版年
2023