立式泵站机组状态评价研究——以前柳林泵站为例
Research on the units state evaluation of vertical pumping station:a case study of Qianliulin pumping station
刘凯华 1王建慧 2吕涛 1化全利1
作者信息
- 1. 北京市南水北调团城湖管理处 北京 100195
- 2. 北京市水科学技术研究院 北京 100048
- 折叠
摘要
为对泵站机组运行过程中的性能水平和退化状态进行精确量化评估,以前柳林泵站为例,开展机组健康状态评价研究.通过构建目标层、设备层、要素层和指标层等4个层次的评价体系,筛选影响设备状态的关键指标参数,并给出评价标准,采用层次分析法量化计算泵站机组评分,实现了泵站机组实时评价,前柳林泵站案例表明评价结果能够反映机组状况,可以为泵站运维决策提供支撑.
Abstract
To accurately quantify the performance and degradation of the pumping station,the health sta-tus evaluation of the unit was conducted.Given the complex structure and numerous influencing factors of pumping station units,a four-level evaluation system was established,consisting of the target layer,equip-ment layer,factor layer,and index layer.The key index parameters affecting the equipment status were screened,and the evaluation standard was defined.The analytic hierarchy process was applied to quanti-tatively calculate the scores of the pumping station unit,enabling real-time evaluation of its condition.The case study of Qianliulin pumping station demonstrated that the evaluation results reflected the status of the unit and provided support for the operation and maintenance decision.
关键词
立式泵站/状态评价/层次分析法Key words
vertical pumping station/state evaluation/analytic hierarchy process引用本文复制引用
出版年
2024