首页|基于近红外光谱法的血液酒精浓度检测仪

基于近红外光谱法的血液酒精浓度检测仪

扫码查看
针对解决呼气式酒精检测仪存在飞沫传播风险的问题,提出了一种基于近红外光谱法的便携式无污染血液酒精浓度检测方案。使用硬件完成信号采集、放大、滤波再放大,利用软件完成卡尔曼滤波、三样条插值法去基等算法获取标准的脉搏波信号。在上位机中通过呼气式的测量结果与脉搏波信号的幅值建立数学模型,将数学模型写入单片机实现离线测量。通过实验测试验证数学模型精度。结果表明,其满足相对误差小于10%的精度要求,符合实际使用需求。
Alcohol Concentration Detector Based on Near Infrared Spectroscopy
In order to solve the problem of droplet transmission risk of breath alcohol detector,a portable and pollution-free blood alcohol concentration detection scheme based on near-infrared spectroscopy is proposed.we successively completed the signal acquisition,amplification,filtering and re-amplification with hardware,and obtained the standard pulse wave signal with software algorithms such as Kalman filtering and three-sample interpolation method to remove the base.Later,the mathematical model is established in the upper computer by the measurement results of the expiratory type and the amplitude of the pulse wave signal,and the mathematical model is written into the microcontroller to realize the offline measurement.The accuracy of the mathematical model is tested through validation experiments.The results show that it meets the accuracy requirement,the relative error is less than 10%and meets the practical requirements.

non-destructive alcohol detectionnear infrared spectroscopyfingertip signalkalman filterthree-sample interpolation

凌振宝、宋诚、欧馨雅、梁淦

展开 >

吉林大学仪器科学与电气工程学院,长春 130026

无损酒精检测 近红外光谱法 指尖信号 卡尔曼滤波器 三样条插值法

大学生创新创业计划基金资助项目

202110183278

2024

吉林大学学报(信息科学版)
吉林大学

吉林大学学报(信息科学版)

CSTPCD
影响因子:0.607
ISSN:1671-5896
年,卷(期):2024.42(4)