首页|核电阀门电动头减振方案设计与可行性评估

核电阀门电动头减振方案设计与可行性评估

扫码查看
某核电机组阀门电动头振动较高,已出现多次电路板卡电容及电阻脱落问题,严重影响设备可靠性.通过数值仿真及振动测试结果分析,确定振动原因是前置泵产生的激励载荷经管道传递至阀门处,阀门固有频率与前置泵叶频接近,导致共振.根据阀门振动原因、结构形式及现场空间,提出了减振方案,即在电动头两端增加动力吸振器,抑制阀门振动,最后对该减振方案进行了测量评估.结果表明,阀门振动降幅超过80%,为后续振动治理提供了参考.
Design and Feasibility Evaluation of Vibration Reduction of Electric Actuator of Nuclear Power Valve
The vibration of the valve actuator of nuclear power unit is high,which has led to the falling off of the capacitance and resistance of the circuit board for many times.This seriously affects the reliability of the equipment.Through numerical simulation and experimental testing analysis,the vibration cause found is that the excitation load generated by the front pump is transmitted to the valve through the pipe-line,and the natural frequency of the valve is close to the blade frequency of the front pump,which results in resonance.According to the cause of vibration,structure form and site space,a-vibration reduction design is carried out for the valve:dynamic vibration absorbers are added at both ends of the valve elec-tric actuator to suppress valve vibration.Finally,the vibration reduction scheme is measured and evalua-ted.The results show that the proportion of the vibration reduction of the valve is over 80%,which pro-vides a reference for the follow-up vibration treatment.

electric actuator of valvecause of vibrationvibration reduction designfeasibility assessment

孙月、刘天彦、韩超、卢军、张鲲

展开 >

中国核动力研究设计院,四川成都 610213

阀门电动头 振动原因 减振设计 可行性评估

2024

成都大学学报(自然科学版)
成都大学

成都大学学报(自然科学版)

影响因子:0.357
ISSN:1004-5422
年,卷(期):2024.43(4)