In order to solve the problem of serious harmonic interference caused by the reverse superposition of operating current in the online calibration of low-voltage current transformers,a harmonic extraction and reverse superposition method of current signals is proposed to reduce high-order harmonics in the current.Firstly,this method uses fast Fourier transform(FFT)to analyze and process the grid signal.Then,a high-pass filter is designed to filter out the harmonic components of the grid current.Finally,reverses the direction and superimposes it with the grid current signal to reduce the high-order harmonic components.The results show that the high-order harmonic components in the simulated signal are reduced by 99%.When the high-order harmonic components in the actual signal are small,the harmonic components are reduced by 80%.
关键词
低压电流互感器/快速傅里叶变换/有限脉冲响应/电流反向叠加
Key words
low-voltage current mutual inductor/fast Fourier transform(FFT)/finite impulse response(FIR)/current reverse superposition