首页|高温高压下湿空气循环中增湿塔的计算研究

高温高压下湿空气循环中增湿塔的计算研究

扫码查看
Study on Calculations of Humidification Tower with Humid Air Turbine Cycle at High Temperature and Pressure
Humidification is an important step in humid air turbine system. The calculation on humidification is carried out at 423.15-573.15K, 5-15 MPa. The results suggest that to produce high-enthalpy moist air, high water temperature and large water flow are needed. The water temperature is the most sensitive parameter to the humidification tower. And it is better for the humidification tower to work at temperature higher than 523 K when the system pressure is higher than 5 MPa. The comparison between the model used in this paper and ideal model shows that the ideal model can be used in simulation to simply the calculation when the temperature is lower than473 K and pressure is lower than 5 MPa.

humidifierhumidificationhumid airturbinehumiditygas-liquid equilibrium

丁皓、陆小华、吉晓燕、秦建华

展开 >

Department of Chemical Engineering, Nanjing University of Technology, Nanjing 210009, China

humidifier humidification humid air turbine humidity gas-liquid equilibrium

江苏省自然科学基金国家自然科学基金国家自然科学基金国家自然科学基金

BK97124203760322992561620236010

2004

中国化学工程学报(英文版)
中国化工学会

中国化学工程学报(英文版)

CSTPCDSCIEI
影响因子:0.818
ISSN:1004-9541
年,卷(期):2004.12(4)
  • 1