首页|阴极保护在乙炔湿式气柜钟罩外壁的应用

阴极保护在乙炔湿式气柜钟罩外壁的应用

扫码查看
内蒙古某化工厂乙炔湿式气柜钟罩由于检修施工周期紧,每道涂层未完全固化,就进行下一道施工,导致涂层本身存在缺陷,长时间运行后出现龟裂、剥离等现象,钟罩外壁严重生锈,甚至出现穿孔现象,存在较大安全隐患.为控制气柜钟罩外壁腐蚀,前期采取固定区域安装镁阳极和锌阳极,悬挂腐蚀试片测试腐蚀速率,得到镁阳极的防腐蚀效果最佳.后期通过理论计算以及合理布置阳极,在检修期施工安装,安装完成后测试阴极保护效果满足≤-0.85 V(vs CSE).通过阴极保护联合现有涂层可减缓或抑制钟罩外壁腐蚀,延长其使用寿命.
Application of Cathodic Protection on the Outer Wall of Acetylene Wet Gas Cabinet Bell Cover
In response to the tight maintenance schedule of the acetylene wet gas cabinet bell cover at a chemical plant in Inner Mongolia,the subsequent layers of coating were carried out before the previous coatings had fully cured,leading to defects in the coating itself. After long-term operation,phenomena such as cracking and peeling occurred,and the outer wall of the bell cover became severely rusted,even perfora-ted,posing a significant safety hazard. To control the corrosion of the outer wall of gas cabinet bell cover,the magnesium anode and zinc anode were installed in the fixed area in the early stage,and the corrosion rate was tested by hanging corrosion coupons to get the best anti-corrosion effect of magnesium anode. Based on theoretical calculations and the proper arrangement of anodes in the later stage,construction and installa-tion carried out during the maintenance period,and the cathodic protection effect was tested to meet≤-0.85 V (vs CSE) after the installation was completed. By combining cathodic protection with existing coatings,corrosion on the outer wall of the bell cover was slowed or suppressed,thereby extending its service life.

cathodic protectioncorrosionwet gas cabinetclock cover outer wall

祖运鹤、李存文、李鸿达、田丰、谢凡、陈亚平

展开 >

中国机械总院集团武汉材料保护研究所有限公司 特种表面保护材料及应用技术国家重点实验室,湖北 武汉 430030

中盐吉兰泰氯碱化工有限公司,内蒙古 阿拉善 750336

阴极保护 腐蚀 湿式气柜 钟罩外壁

2024

材料保护
武汉材料保护研究所,中国腐蚀与防护学会 中国表面工程协会

材料保护

CSTPCD
影响因子:1.129
ISSN:1001-1560
年,卷(期):2024.57(9)