材料科学技术(英文版)2021,Vol.66Issue(7) :57-63.

A graphene-laminated electrode with high glucose oxidase loading for highly-sensitive glucose detection

Yabin Hao Minghe Fang Chuan Xu Zhe Ying Han Wang Rui Zhang Hui-Ming Cheng You Zeng
材料科学技术(英文版)2021,Vol.66Issue(7) :57-63.

A graphene-laminated electrode with high glucose oxidase loading for highly-sensitive glucose detection

Yabin Hao 1Minghe Fang 1Chuan Xu 2Zhe Ying 2Han Wang 1Rui Zhang 3Hui-Ming Cheng 4You Zeng1
扫码查看

作者信息

  • 1. Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China;School of Materials Science and Engineering, University of Science and Technology of China, Shenyang 110016, China
  • 2. Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
  • 3. Liaoning Cancer Hospital and Institute, Shenyang 110042, China
  • 4. Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China;School of Materials Science and Engineering, University of Science and Technology of China, Shenyang 110016, China;Shenzhen Geim Graphene Center, Tsinghua-Berkeley Shenzhen Institute, Shenzhen 518055, China
  • 折叠

Abstract

Graphene oxide (GO) has received considerable attention for glucose detection because of high surface area,abundant functional groups,and good biocompatibility.Defects and functional groups of the GO are beneficial to immobilization of glucose oxidase (GOD),but sacrificing electron-transfer capability for highly-sensitive detection.In order to obtain high GOD loading and highly-sensitive detection of biosensors,we first designed and fabricated a graphene-laminated electrode by combining GO and edgefunctionalized graphene (FG) layers together onto glassy-carbon electrode.The graphene-laminated electrodes exhibited faster electron transfer rate,higher GOD loading of 3.80 × 10-9 mol.cm-2,and higher detection sensitivity of 46.71 μA·mM-1·cm-2 than other graphene-based biosensors reported in literature.Such high performance is mainly attributed to the abundant functional groups of GO,high electrical conductivity of FG,and strong interactions between components in the graphene-laminated electrodes.By virtue of their high enzyme loading and highly-sensitive detection,the graphene-laminated electrodes show great potential to be widely used as high-performance biosensors in the field of medical diagnosis.

Key words

Graphene/Laminated structure/Electrode/Glucose detection/Biosensor

引用本文复制引用

基金项目

authors thank Dr.Shijing Wei for helpful discussion.The authors acknowledge financial supports from the National Natural Sci(51802317)

Liaoning Natural Science Foundation(2019JH3/30100008)

Liaoning Key Research & Development Project(2019JH2/10300045)

Joint Fund for Advanced Equipment and Aerospace Science and Technology of China(6141B061306)

出版年

2021
材料科学技术(英文版)
中国金属学会 中国材料研究学会 中国科学院金属研究所

材料科学技术(英文版)

CSTPCDCSCDSCI
影响因子:0.657
ISSN:1005-0302
被引量1
参考文献量61
段落导航相关论文