材料科学技术(英文版)2021,Vol.72Issue(13) :122-131.

2D-titanium carbide (MXene) based selective electrochemical sensor for simultaneous detection of ascorbic acid, dopamine and uric acid

Nagaraj Murugan Rajendran Jerome Murugan Preethika Anandhakumar Sundaramurthy Ashok K.Sundramoorthy
材料科学技术(英文版)2021,Vol.72Issue(13) :122-131.

2D-titanium carbide (MXene) based selective electrochemical sensor for simultaneous detection of ascorbic acid, dopamine and uric acid

Nagaraj Murugan 1Rajendran Jerome 1Murugan Preethika 1Anandhakumar Sundaramurthy 2Ashok K.Sundramoorthy1
扫码查看

作者信息

  • 1. Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur, 603 203, Tamil Nadu, India
  • 2. SRM Research Institute, SRM Institute of Science and Technology, Kattankulathur, 603 203, Tamil Nadu, India
  • 折叠

Abstract

Two-dimensional (2D) titanium carbide (MXene) nanosheets exhibited excellent conductivity,flexibility,high volumetric capacity,hydrophilic surface,thermal stability,etc.So,it has been exploited in various applications.Herein,we report synthesis of mixed phase 2D MXene as a catalytic material for simultaneous detection of important biomolecules such as ascorbic acid (AA),dopamine (DA) and uric acid (UA),Crystalline structure,surface morphology and elemental composition of mixed phase titanium carbide (Ti-C-Tx) MXene (Tx =-F,-OH,or-O) nanosheets were confirmed by X-ray diffraction (XRD),Raman spectroscopy,high-resolution transmission electron microscopy (HR-TEM),high-resolution scanning electron microscopy (HR-SEM) and Energy-dispersive X-ray spectroscopy (EDS) mapping analysis.Furthermore,Ti-C-Tx modified glassy carbon electrode (GCE) was prepared and its electrochemical properties are studied by cyclic voltammetry (CV) and differential pulse voltammetry (DPV).It was found that Ti-C-Tx modified GCE (Ti-C-Tx/GCE) showed excellent electrocatalytic activity and separated oxidation peaks of important biomolecules such as AA (at 0.01 V),DA (at 0.21 V) and UA (at 0.33 V).Also,Ti-C-Tx/GCE sensor is enabled their simultaneous detection in physiological pH from 100 to 1000 μM for AA,0.5-50 μM for DA and 0.5-4 μM & 100-1500 μM for UA.The limit ofdetection's (LOD) was estimated as 4.6 μM,0.06 μM and 0.075 μM for AA,DA and UA,respectively.Moreover,real sample analysis indicated that spiked AA,DA and UA can be determined accurately by Ti-C-Tx/GCE with the recovery ratio in the range between 100.5%-103% in human urine samples.The proposed Ti-C-Tx modified electrode exhibited good stability,selectivity and reproducibility as an electrochemical sensor for the detection ofAA,DA and UA molecules.

Key words

Titanium carbide/Dopamine/Uric acid/Ascorbic acid/Electrochemical sensor

引用本文复制引用

基金项目

We acknowledge the financial support from the Science and Engineering Research Board (SERB),India(ECR/2016/001446)

Department of Science and Technology (International Bilateral Cooperation Division) for financial support through "INDO-RUSSIA P(INT/RUS/RFBR/385)

出版年

2021
材料科学技术(英文版)
中国金属学会 中国材料研究学会 中国科学院金属研究所

材料科学技术(英文版)

CSTPCDCSCDSCI
影响因子:0.657
ISSN:1005-0302
参考文献量78
段落导航相关论文