重庆电力高等专科学校学报2024,Vol.29Issue(2) :17-21.

600 MW超临界机组凝结水泵节能改造实践

A Study on the Practice of Energy Conservation Renovation of Condensate Pumps of the 600 MW Supercritical Unit

白春林 董玉雯
重庆电力高等专科学校学报2024,Vol.29Issue(2) :17-21.

600 MW超临界机组凝结水泵节能改造实践

A Study on the Practice of Energy Conservation Renovation of Condensate Pumps of the 600 MW Supercritical Unit

白春林 1董玉雯1
扫码查看

作者信息

  • 1. 佛山恒益热电有限公司,广东 佛山528131
  • 折叠

摘要

探讨了凝结水泵变频调速技术的原理,并进行了变频改造试验分析和节能经济性分析.经过凝结水泵变频改造后,机组在低负荷时可节约电率51%,在高负荷时可节约电率13% ~35%,节电效果显著,为企业节省了成本.

Abstract

This paper explores the principle of the technology of frequency control of motor speed for condensate pumps,and conducts the analyses of frequency conversion renovation experiments and energy conservation econo-my. After the frequency conversion renovation of the pumps,the unit can save about 51% of electricity at low loads and 13% ~15% at high loads. The electricity-saving effect is remarkable,saving costs for enterprises.

关键词

600/MW超临界机组/凝结水泵/节能/变频调速

Key words

600 MW supercritical unit/condensate pump/energy conservation/frequency control of motor speed