降低杆塔的冲击接地电阻是提高输电线路反击耐雷水平的有效措施,而目前的各种降阻方法普遍存在技术经济性及施工难度难以兼顾的问题.在接地体上添加短导体,兼具降阻和施工简便的优势.为此,研究利用三维交错结构短导体降低杆塔冲击接地电阻的方法,并给出短导体的参数优化方法.首先,考虑土壤非线性电离影响在内,采用CDEGS软件对添加短导体接地装置时的冲击接地电阻进行计算,计算结果表明三维交错结构短导体具有更好的降阻效果;然后,以单位长度降阻率和最小冲击接地电阻为指标,对三维交错结构短导体的长度和间隔进行参数优化;最后,以1 000 Ω ⋅ m土壤电阻率为例,求得短导体的最优长度和最优间隔分别为1.1、2.8 m,添加三维交错结构短导体的接地装置可降低16.52%的冲击接地电阻.研究结果可为输电杆塔接地装置的设计提供方法指导.

Abstract

Reducing the impulse grounding resistance of transmission towers is an effective measure to improve the lightning surge withstand capability of transmission lines.However,current methods for reducing resistance generally face challenges in balancing technical and economic feasibility,as well as construction difficulty.Adding short conductors to the grounding device combines the advantages of resistance reduction and simplified construction.This paper explores the use of three-dimensional interleaved short conductors to reduce the impulse grounding resistance of transmission towers,and provides the parameter optimization approach for short conductors.Firstly,considering the influence of nonlinear ionization in the soil,the impulse grounding resistance of grounding device with short conductors is calculated by the CDEGS software.Results indicate that the short conductors with three-dimensional interleaved structure exhibit superior resistance reduction effects.Subsequently,taking the resistance reduction rate per unit length and minimum impulse grounding resistance as indicators,the length and spacing arrangements of three-dimensional interleaved short conductors are optimized.Finally,taking a soil resistivity of 1000 Ω·m as an example,the optimal length and spacing of the short conductors are determined to be 1.1 m and 2.8 m,respectively.The addition of the three-dimensional interleaved structure short conductors to the grounding device can reduce the impulse grounding resistance by 16.52%.This paper provides a method guidance for the design of transmission tower grounding device.

关键词

三维交错结构短导体/接地优化设计/杆塔接地装置/降阻/CDEGS软件

Key words

three-dimensional interleaved short conductors/grounding optimization design/tower grounding device/reduce resistance/CDEGS software