大氮肥2024,Vol.47Issue(4) :228-230.

一段转化炉工艺空气盘管泄漏原因分析

CAUSE ANALYSIS FOR PROCESS AIR COILS LEAKAGE OF PRIMARY REFORMER

廖新文
大氮肥2024,Vol.47Issue(4) :228-230.

一段转化炉工艺空气盘管泄漏原因分析

CAUSE ANALYSIS FOR PROCESS AIR COILS LEAKAGE OF PRIMARY REFORMER

廖新文1
扫码查看

作者信息

  • 1. 中国石油乌鲁木齐石化分公司,新疆乌鲁木齐 830019
  • 折叠

摘要

介绍一段转化炉工艺空气盘管泄漏的经过,通过对泄漏部位周边进行硬度、壁厚和晶相的检测,判定泄漏部位管线的金相组织存在 3~4 级球化,并对盘管进行了修补、整体更换及防护措施,问题得到了解决.

Abstract

This article introduces the process of air coils leakage in the primary reformer.By testing the hardness,wall thickness,and crystal phase around the leakage site,it is determined that there is a 3~4 level spheroidization in the metallographic structure of the pipeline at the leakage site.The coil was repaired,replaced as a whole,and the protective measures were taken to solve the problem.

关键词

一段转化炉/工艺空气盘管/泄漏

Key words

primary reformer/process air coils/leakage