办公楼作为工厂内人员最密集场所,防排烟设计十分重要,将工厂办公楼定义为其他公共场所,主要讨论其在GB 55037-2022《建筑防火通用规范》、GB 55036-2022《消防设施通用规范》和GB 51251-2017《建筑防烟排烟系统技术标准》下的防排烟设计,并比较各种优化方案,选出最优的防排烟设计方案.
THE SMOKE PREVENTION AND EXHAUST DESIGN FOR A PETROCHEMICAL PLANT OFFICE BUILDING
As the most densely populated area in the factory,the smoke management design of the office building is very important.This article defines this office building as an"other public place"and mainly discusses its smoke management design under GB 55037-2022"General Code for Fire Protection of Buildings and Constructions",GB 55036-2022"General Code for Fire Protection Facilities",and GB 51251-2017"Technical Standard for Smoke Management Systems in Buildings".Through discussing various optimization schemes,the optimal smoke management design scheme is derived.

smoke control zonenatural smoke exhaustmechanical smoke exhaustnatural smoke prevention