首页|高压液氨泵驱动端振动值高原因分析及改进措施

高压液氨泵驱动端振动值高原因分析及改进措施

扫码查看
针对尿素装置高压液氨泵在运行中出现振动值缓慢上涨的现象,采用先进的频谱技术判断泵体故障点,解体检查分析故障原因,通过更换转子和主油泵梅花软连接、改进油密封测振环等措施,成功消除了液氨泵振动值高的故障,确保了装置安全稳定的长周期运行.
ANALYSIS OF HIGH VIBRATION ON DRIVE END OF HIGH PRESSURE LIQUID AMMONIA PUMP AND ITS IMPROVEMENTS
With regard to the growing of vibration value of high pressure liquid ammonia pump in urea plant,the advanced frequency spectrum technology was used to diagnose the defects on the pump body.Analyzed the failure reason after disassemble and detection,some measures were taken to eliminate the vibration failure successfully,such as changing the rotator and the main oil pump wabbler,modifying the oil seal vibration detection ring,which ensured the safe,stable and long term operation of the plant.

high pressure liquid ammonia pumphigh vibration valuefrequency spectrum analysiswabbleroil seal vibration detection ring

秦荣、谢贵敏、李碧松

展开 >

重庆建峰化工股份有限公司,重庆 408017

高压液氨泵 振动值高 频谱分析 梅花软连接 油密封测振环

2024

大氮肥
中国石化集团宁波技术研究院

大氮肥

影响因子:0.15
ISSN:1002-5782