Research on Environmental Corrosiveness Monitoring of PCCP Pipelines Based on Temperature Variation
In order to accurately assess the environmental corrosion dynamics of prestressed concrete cylinder pipes(PCCP)in the Dahuofang Water Transfer(Phase II)Project,and to explore the necessity of dynamic monitoring of environmental corrosion in engineering contexts,this paper utilizes ECI intelligent monitoring devices to conduct systematic environmental corrosion dynamic tests on buried pipelines.The paper briefly describes the system components and installation structure of the ECI equipment.The research indicates that an increase in environmental temperature enhances the corrosion activity of PCCP pipelines.This finding provides scientific evidence for the necessity of implementing dynamic monitoring of environmental corrosion in engineering projects.The success of this experiment and the dynamic monitoring of environmental corrosion in the Dahuofang Water Transfer Project can provide practical references for pipeline engineering facing similar environmental corrosion issues.
ECI intelligent monitoringenvironmental water corrosivenesssoil corrosivenessrebar self-corrosioncathodic protection monitoring