摘要

研究配变重过载下的配网运营动态监控平台实时任务容错调度算法,以解决配网运营动态监控平台执行配变重过载监控任务时可调度性差的问题.依据分层调度思想,将实时任务容错调度划分为上层调度算法和下层调度算法,通过上层调度算法利用 Logistic 模型预测是否存在配变重过载情况,存在配变重过载情况时,进入下层调度算法.下层调度算法利用平台的优先级属性列表,建立平台管理机执行配变重过载动态监控任务时的有效传递函数,利用码元调制方法获取平台任务调度输出,保障配网运营动态监控平台稳定执行配变重过载动态监控任务.实例分析结果表明,配网运营动态监控同时执行 30 个配变重过载动态监控任务时,其容错调度成功率高于 93%,验证该算法具有良好的实时任务容错调度有效性.

Abstract

This paper studied the real-time task fault-tolerant scheduling algorithm of the distribution network dynamic monitoring platform with heavy-overload distribution transformer in order to solve the problem of poor schedulability of distribution network dynamic monitoring platform when performing heavy overload monitoring task of distribution trans-former.According to the layered scheduling idea,fault-tolerant scheduling of real-time tasks were classified into upper scheduling algorithm and lower scheduling algorithm.Through the upper scheduling algorithm,the logistic model was used to predict whether there existed heavy-overload distribution transformer,and transfered to lower scheduling algo-rithm when encountering heavy overload.The lower scheduling algorithm used the priority attribute list of the platform to establish effective transfer function when platform manager performs dynamic monitoring task,and adopted symbol mod-ulation method to obtain scheduling output of the platform task,so as to ensure stable implementation of dynamic monito-ring distribution transformer overload.The proposed algorithm was proved by case analysis to achieve a success rate of fault-tolerant scheduling higher than 93%when coping with simultaneous 30 dynamic monitoring tasks of heavy-overload distribution network operation,and satisfactorily effective in real-time task fault-tolerant scheduling.

关键词

配变/重过载/配网运营/动态监控平台/实时任务/容错调度算法

Key words

distribution transformer/heavy overload/distribution network operation/dynamic monitoring platform/real-time task/fault-tolerant scheduling algorithm