首页|变电站监控信息自动验收技术应用

变电站监控信息自动验收技术应用

扫码查看
针对传统的变电站监控信息验收方式采用逐点实传、人工核对的方式,耗时耗力,提出了一种监控信息自动验收解决方法,采用专用工具模拟变电站内间隔层设备,自动触发信号至主站,满足全回路验收要求.
Application of Automated Pre-acceptance Examination Technology for Substation Monitoring Information
Conventional pre-acceptance examination method of substation monitoring information uses point-to-point real transmission and manual verification,which is time-consuming and labor-intensive.This paper proposes a solution for au-tomated pre-acceptance examination of monitoring information,which uses a dedicated tool to simulate the equipment in bay-layer of the substation and automatically trigger signals to the master station,meeting the requirements for full circuit examination.

monitoring informationautomated pre-acceptance examinationbay-layer devicemaster station

李翔波、龚祥云

展开 >

国网河南省电力公司商丘供电公司,河南 商丘 476000

监控信息 自动验收 间隔层设备 主站

2024