首页|一种能自净的变电站电抗器室环境治理方法

一种能自净的变电站电抗器室环境治理方法

扫码查看
在变电站中,220 kV主变压器变低串联电抗器长期运行会产生大量热量,而长期积聚的灰尘会对设备散热和绝缘性能造成影响.提出了一种电抗器室自动清灰系统,旨在解决这些问题.探讨了该系统的设计原理、工作机制和优化方法,并通过实验和实际应用验证了其效果.
Environment Management Method for Substation Reactor Room Enabling Automated Cleaning
In a substation,long-term operation of 220 kV main transformer and its connected shunt reactor generates a significant amount of heat,while the accumulation of dust over time can affect the equipment's heat dissipation and insula-tion performance.This paper proposes an automatic dust removal system for the reactor chamber to address these issues.The design principles,operational mechanisms,and optimization methods of this system are be discussed,and its effec-tiveness is validated through experiments and practical applications.

substationseries reactorheat dissipationdust removal system

雷剧璋、冯镇生

展开 >

广东电网有限责任公司佛山供电局,广东 佛山 528000

变电站 串联电抗器 散热 除尘装置