首页|低压电动机配电电缆芯数选择的新观点

低压电动机配电电缆芯数选择的新观点

扫码查看
低压电动机有使用4芯(3相+1PE)电缆配电的,也有使用3芯(3相)电缆配电的,其中3芯电缆配电的使用未见相关规范依据.直到GB 50217—2018《电力工程电缆设计标准》实施,首次提出TN-S系统低压电动机配电宜选用3芯电缆,规范正文及条文说明中明确了在满足特定条件时可使用3芯电缆给低压电动机配电.从电缆选型原则及电机的保护要求为切入点,以解读规范内容为重点,结合实际来论述电缆芯数的选择方式.
New Perspective on Determining Core Number of Distribution Cable for Low-voltage Motors
Currently both 4-cores (3-phase +1 PE)and 3-cores (3-phase)cable are used for power distribution of low-voltage motors. In which to our knowledge there was no standard basis for the use of 3-core cable Until the presence and in force of GB 50217—2018 standard for design of cables of electric power engineering. This standard for the first time put forward the expression that 3-core cables should be used for low-voltage motor distribution of TN-S system,and clarifies the possibility of using 3-core cables when specific conditions are met. Through the elaboration of the cable selection prin-ciple and the interpretation of the GB 50217 standard,this paper discusses the selections of multi-core cable for low-volt-age motor distribution under different conditions.

TN-S system3-core cablePE conductor

杨鹏

展开 >

京鼎工程建设有限公司,北京 100011

TN-S系统 3芯电缆 PE导体

2024