利用微地形因子、气象条件及同期覆冰观测资料等9个评价指标,采用主成分分析算法对30个典型的输电线路微地形小区域样本进行计算,并依据方差贡献率建立应力波除冰器部署位置综合评价模型.提取模型中累计方差贡献率大于90%的前4个主成分计算得到了满足正态分布特征的样本综合得分,并给出了应力波发生器在30个待安装区域的优先级.
The present work used 9 evaluation indicators,including microtopography factors,meteorological conditions,ice cover observation data during the same period,etc.,and employed principal component analysis algorithm to calculate 30 typical cases of transmission line small micro-terrain areas,and to establish a comprehensive evaluation model for de-ployment positions of stress wave defrosters according to the variance contribution rate.Comprehensive scores of the cases with normal distribution were calculated by selecting the first four principal components whose cumulative variance contri-bution rate was greater than 90%.Furthermore,the priority of the stress wave generator in the 30 areas to be installed was given.