首页|螺旋锚基础在高原地区750 kV输电线路应用的局限性

螺旋锚基础在高原地区750 kV输电线路应用的局限性

扫码查看
螺旋锚基础因便于机械化施工、余土量少等优点,广泛应用于平原地区河网、泥沼、沿海滩涂等软弱性地质条件的低电压等级输电线路.然而对于高原地区土质较硬或含碎石土层等地质条件下螺旋锚基础是否适用,尚没有明确的结论.结合高原地区750 kV输电线路工程的基础设计情况,从螺旋锚基础的加工工艺、施工机械选择、与常规基础经济性比较等方面入手,讨论分析了高原地区高电压等级输电线路中螺旋锚基础的适用局限性.
Applicative Limitation of Helical Anchor Foundation in Plateau Area 750 kV Transmission Lines
Helical anchor foundation is widely used in low-voltage transmission lines with soft geological conditions,such as river network in plain area,mud marsh,coastal beach,etc.,however,there is no definite conclusion on the applicabili-ty of helical anchor foundation under the geological conditions such as hard soil or gravel-bearing soil in the plateau area. Based on the foundation design of 750 kV transmission line project in plateau area,starting with the processing technology of helical anchor foundation,selection of construction machinery,and comparison with conventional foundation in econo-my,this paper discusses and analyzes the limitation of application of helical anchor foundation for high voltage grade transmission lines in plateau area.

helical anchor foundationlimitationgravel geological condition

殷黎明、王路路

展开 >

中国电建集团河南省电力勘测设计院有限公司,河南 郑州 450007

螺旋锚基础 局限性 碎石地质条件

2024

电工技术
重庆西南信息有限公司(原科技部西南信息中心)

电工技术

影响因子:0.177
ISSN:1002-1388
年,卷(期):2024.(13)