首页|文物建筑群电气火灾监控系统的设置探讨

文物建筑群电气火灾监控系统的设置探讨

扫码查看
导致文物建筑群起火的主要因素之一是电弧性接地故障,而对配电系统安装电气火灾监控系统是预防电气火灾的有效方法.通过分析建筑群配电系统的配电方式和接地电弧引发电气火灾的成因,探讨文物建筑群科学设置电气火灾监控系统的方法,提高文物建筑的消防安全水平.
Discussion on the Deployment of Electrical Fire Monitoring System in Heritage Building Complexes
One of the main factors causing fires in heritage building complexes is arcing grounding faults,against which the effective preventive measure is to deploy an electrical fire monitoring subsystem in the distribution system.By analy-zing the distribution modes of heritage building power distribution system and the causes of fire-hazardous grounding arcs,this paper discusses the methods of scientifically deploying electrical fire monitoring systems in heritage buildings,aiming at fire safety promotion of heritage building complexes.

heritage building complexesgrounding faultelectrical firemonitoring

向勇

展开 >

北京艺术博物馆,北京 100013

文物建筑群 接地故障 电气火灾 监控

2024

电工技术
重庆西南信息有限公司(原科技部西南信息中心)

电工技术

影响因子:0.177
ISSN:1002-1388
年,卷(期):2024.(13)