LOCA监测系统是运行人员监测反应堆堆芯状态的重要系统,运行技术规范中要求LOCA处理部分故障时,机组要在6 h内降功率到15%Pn以下,因此LOCA监测系统的可靠性影响机组的安全稳定运行.分析了当前各电厂中使用的LOCA监测系统的结构及其优劣,提出通过冗余改造来提升系统的可靠性,同时分析了两种可行的冗余改造方案.
Reliability Analysis of LOCA Monitoring System in Nuclear Power Plants and Construction of Its Backup System
The LOCA monitoring system is an important system for operators to monitor the state of the reactor core.In the operational technical specifications,it is required that when the LOCA deals with some faults,the unit should reduce its power to below 15%Pn within 6 hours.Therefore,the reliability of the LOCA monitoring system affects safe and sta-ble operation of the unit.This paper analyzes structure and advantage of LOCA monitoring systems currently used in vari-ous power plants,outlines the improvement of system reliability through retrofit for redundancy,and analyzes two feasi-ble retrofit schemes.