以某铜杆生产企业的连铸连轧生产线的夹送辊和甩线电机故障处理为工程实例,根据电磁波传输线理论,通过分析电缆电容变大的原因及对电机的影响,阐述变频电机端尖峰电压和电流尖峰的形成过程,得出电机绕组匝间绝缘击穿的结论,并提出解决方案.
Analysis and Solution of Motor Cable Defects on the Output Side of Invertor
In a copper rod plant,in its continuous casting and rolling production line the pinch rolling motor and the laying head motor had broken down,and motors troubleshoot is as a engineering examples.according to the electromagnetic wave transmission line theory,by analysis of the causes about cable capacitances increase,we can learn the cable capacitances how to influence the motors,how to form the motor end peak voltage and current peak,therefore motor winding insulator was breakdown,and put forward the solution.