电工技术2024,Issue(23) :180-182,185.DOI:10.19768/j.cnki.dgjs.2024.23.043

变频器输出侧电机电缆缺陷影响分析与对策

Analysis and Solution of Motor Cable Defects on the Output Side of Invertor

丘志伟
电工技术2024,Issue(23) :180-182,185.DOI:10.19768/j.cnki.dgjs.2024.23.043

变频器输出侧电机电缆缺陷影响分析与对策

Analysis and Solution of Motor Cable Defects on the Output Side of Invertor

丘志伟1
扫码查看

作者信息

  • 1. 深圳市水务技术服务有限公司,广东 深圳 518049
  • 折叠

摘要

以某铜杆生产企业的连铸连轧生产线的夹送辊和甩线电机故障处理为工程实例,根据电磁波传输线理论,通过分析电缆电容变大的原因及对电机的影响,阐述变频电机端尖峰电压和电流尖峰的形成过程,得出电机绕组匝间绝缘击穿的结论,并提出解决方案.

Abstract

In a copper rod plant,in its continuous casting and rolling production line the pinch rolling motor and the laying head motor had broken down,and motors troubleshoot is as a engineering examples.according to the electromagnetic wave transmission line theory,by analysis of the causes about cable capacitances increase,we can learn the cable capacitances how to influence the motors,how to form the motor end peak voltage and current peak,therefore motor winding insulator was breakdown,and put forward the solution.

关键词

电缆分布电容/反射电压/尖峰电压/电流尖峰/带VPL/du/dt滤波器

Key words

cable capacitance/reflect voltage/peak voltage/current peak/du/dt filter plus VPL

引用本文复制引用

出版年

2024
电工技术
重庆西南信息有限公司(原科技部西南信息中心)

电工技术

影响因子:0.177
ISSN:1002-1388
段落导航相关论文