分析了针对某 35kV集电线路频繁遭遇雷击跳闸挑战所采取的防雷对策.其中,差异化避雷器布置策略以其卓越的可行性、效率与经济性等特点成为推荐的优选方案,该策略通过精确部署避雷器来调控雷电流的流向与强度,进而减轻雷击对电力线路造成的冲击与损害.在差异化避雷器布置策略执行过程中主要依据杆塔的具体设计、地理环境的特性及历史雷击记录的综合分析,规划了避雷器的安装位置、数量及相位分配,旨在构建一个适应性强、防护效果显著的防雷网络.经过实际测试验证了差异化防雷技术在 35kV 集电线路上的卓越成效,具有借鉴和推广意义.
Research on Lightning Protection Technology of 35 kV Collector Line
This paper provides an in-depth analysis of the lightning protection measures taken to address the frequent lightning-induced tripping challenges faced by a 35 kV power collection line.Among the strategies,the differential light-ning arrester placement strategy stands out as the recommended optimal solution due to its outstanding feasibility,effi-ciency,and cost-effectiveness.This strategy involves the precise deployment of lightning arresters to regulate the flow and intensity of lightning currents,thereby reducing the impact and damage caused by lightning strikes to the power lines.The implementation of the differential lightning arrester placement strategy mainly relies on a comprehensive analysis of the specific design of the towers,the characteristics of the geographical environment,and historical lightning strike records to plan the installation location,quantity,and phase distribution of the arresters.The aim is to create a lightning protection network that is highly adaptable and significantly effective.Practical test data have verified the exceptional effectiveness of the differential lightning protection technology on 35 kV power collection lines,making it a strategy worthy of reference and promotion.

collector linesdifferential lightning protectionlightning arresters

王善军、孙永杰、李波、王栋、张文雅

展开 >

国网青岛供电公司,山东 青岛 266000

国家电网有限公司,北京 100052

集电线路 差异化防雷 避雷器

2024

电工技术
重庆西南信息有限公司(原科技部西南信息中心)

电工技术

影响因子:0.177
ISSN:1002-1388
年,卷(期):2024.(23)