首页|某核电厂发电机定子冷却水系统不锈钢管座开裂原因分析

某核电厂发电机定子冷却水系统不锈钢管座开裂原因分析

扫码查看
某核电厂在功率运行期间,发电机定子冷却水系统不锈钢管座发生泄漏.为查明原因,采用宏观及显微组织分析、成分分析等方法对开裂的管座进行失效分析,结果表明不锈钢管座发生了高周疲劳开裂失效.为此提出相应改进措施,有效地解决了功率运行期间发电机定子冷却水系统不锈钢管座泄漏问题,也为其他机组解决类似问题提供借鉴.
Analysis of Cracking Cause for Generator Stator Cooling Water System Stainless Steel Tube Base in a Nuclear Power Plant
The stainless steel tube base of generator stator cooling water system leaked during the operation of a nuclear power plant.In order to find out the reason,the failure analysis of cracked tube base was carried out by means of macro-scopic and microscopic structure analysis and composition analysis.The results show that the stainless steel tube base has high cycle fatigue cracking failure.Rectification measures have been proposed,the leakage problem of stainless steel tube base of generator stator cooling water system during power operation is effectively solved,and it also provides reference for other units to solve similar problems.

nuclear power plantstainless steel tube basefailure analysishigh cycle fatigue cracking

李志强、陈凯旋

展开 >

海南核电有限公司,海南 昌江 572733

核电厂 不锈钢管座 失效分析 高周疲劳开裂

2024