Improvement and Practice of 10 kW DAM Transmitter Exciter Protection Design Blockade Insufficient
Aiming at the failure of 10 kW Digital Amplitude Modulation(DAM)transmitter in normal and low power,the analysis process,detection principle and maintenance process of the failure are introduced.By improving the design of the transmitter exciter protection,the problem of insufficient blocking of the exciter protection design at low power has been solved.
Digital Amplitude Modulation(DAM)exciter protectionimprove designinsufficient blockade