防雷插座电压保护水平试验方法解析

扫码查看
本文解析了防雷插座电压保护水平的试验方法.首先,介绍了用于测试防雷插座电压保护水平两个常用标准IEC61643-11 和UL1449 的不同要求.其次,基于IEC61643-11 和UL1449 标准对防雷插座电压保护水平进行试验及分析.最后,总结了两种测试方法的优缺点,并指出在实际应用中应根据具体需求选择适合的测试方法,以确保防雷插座的性能和质量.
Analysis of Test Methods for Voltage Protection Level of Surge Protecting Sockets
This article analyzes the testing methods for the voltage protection level of surge protectors.Firstly,it introduces the different requirements of IEC 61643-11 and UL 1449,which are two commonly used standards for testing the voltage protection level of surge protectors.Secondly,it discusses the testing and analysis of the voltage protection level of surge protectors based on the IEC 61643-11 and UL 1449 standards.Finally,it summarizes the advantages and disadvantages of the two testing methods and points out that the appropriate testing method should be chosen according to specific requirements in order to ensure the performance and quality of surge protectors.

surge protectorvoltage protection leveltesting methods analysis

马壮

展开 >

上海市质量监督检验技术研究院 上海 201114

防雷插座 电压保护水平 试验方法分析

上海市质量监督检验技术研究院科研项目