Wall-Mounted Air-Conditioner Closed Wind Deflector Drive Mechanism Study
According to the principle of gear and rack internal meshing transmission,the paper studied the launch and recovery movement of the closed wind deflector driving mechanism in wall-mounted air-conditioner.After detailed analysis of mechanism force and torque characteristics,the corresponding calculation theory was established.Based on the theory proposed in this paper,the theoretical value of eight designs were calculated and compared with experimental data obtained from prototype test.The deviation analysis method proves the validity of this theory effectively and gives out several important guidance of the design.
wall-mounted air-conditionerwind deflector drive mechanismdesign and calculation theoryex-perimentdeviation analysis method