Influence on the Additional Losses of Asynchronous Motors by Rotor Slot Numbers
The article introduces a kind of high power density three-phase asynchronous motor used in rail transit.It first briefly analyzes the influence on the additional losses of motors by rotor slot numbers,and then,conducts a finite element simulation analysis on the additional losses of mo-tors by different rotor slot numbers,at last,the simulation results are verified through the verification test.
three-phase asynchronous motorrotor slot numberadditional lossesfinite element meth-odexperiment