Against problem of the lead head fractures of magnet pole coils in a certain type of locomotive syn-chronous generator,the cause analysis is performed and the corresponding improvement measures are proposed either,to effectively improve the stress level of the lead head,pre-venting recurrence of the fracture failures.
关键词
同步发电机/磁极线圈引线头/可靠性优化设计
Key words
synchronous generator/lead head of mag-net pole coils/reliability optimization design