Improved Design of the Lead Head of Magnet Pole Coils in Locomotive Synchronous Generators
Against problem of the lead head fractures of magnet pole coils in a certain type of locomotive syn-chronous generator,the cause analysis is performed and the corresponding improvement measures are proposed either,to effectively improve the stress level of the lead head,pre-venting recurrence of the fracture failures.
synchronous generatorlead head of mag-net pole coilsreliability optimization design