配网自动化自愈技术的核心内容是通过自愈控制终端装置实现网架供电自动切换、故障隔离和恢复供电,其目标是提高电网的抗干扰能力和可靠性.探讨了配电网在面临规模扩展及新能源接入情况时对自愈技术的需求,分析了多种自愈模式的策略及其优缺点.以强调故障发生时的快速隔离和供电恢复能力为出发点,对主站集中型、主站与级差保护协同型、电压时间型和级差与电压时间混合型策略进行了详细解析.分析结果表明,主站集中型策略具有灵活性高和适应性强等优点,但对通信和图模质量的要求较高;级差保护能够快速实现故障就地隔离,但需与主站协同工作;电压时间型适用于简单网架结构;而混合型结合了多种优点,适用性更广.最后结合工程实践,考虑保障配电网的可靠性和高效运行,提出了馈线自动化的选型应根据供电区域特点和实际需求进行差异化实施的观点.
Analysis of Self-healing Mode in 10 kV Distribution Network
The core content of self-healing technology of distribution network automation is to achieve automatic switching,fault isolation and restoration of grid power supply through the self-healing control terminal device,with the goal of improving the anti-interference ability and reliability of the power grid.The demand for self-healing technology in the face of scale expansion and new energy access is discussed,and various self-healing mode strategies and their advantages and disadvantages are analyzed.Taking the starting point of emphasizing the fast isolation and power restoration capability when fault occurs,the strategies of master station centralized type,master station and differential protection synergy type,voltage-time type and differential and voltage-time hybrid typeare analyzed in detail.The analysis results show that the master station centralized strategy has the advantages of high flexibility and strong adaptability,but has high requirements for communication and module quality;the differential protection can quickly realize fault isolation,but needs to work together with the master station;the voltage time type is suitable for simple grid structure;and the hybrid type combines many advantages has a wider applicability.Finally,combining with the engineering practice and considering to guarantee the reliability and efficient operation of the distribution network,it is proposed that the selection of feeder automation should be differentiated according to the characteristics of the power supply area and the actual demand.

distribution networkself-healing control strategyfeeder automation selectionmaster centralized strategydifferential protection

李如锋、牛理达、栗傲然、韩超超、李伟

展开 >

国网雄安新区供电公司,河北 保定 071700

配电网 自愈控制策略 馈线自动化选型 主站集中型策略 级差保护

2025

电力科学与工程
华北电力大学

电力科学与工程

影响因子:0.675
ISSN:1672-0792
年,卷(期):2025.41(1)