扫码查看
在电力变压器工作过程中,变压器油介质损耗因数过高是常见问题,解决该问题对变压器稳定而有效的运行具有重大意义.文章通过对某电厂110 kV变压器油介质损耗问题的探讨,分析了油介质损耗因数过高问题产生的原因,并提出了加热变压器油、吸附杂质、更换变压器油等应对方法.
Analysis and Countermeasures of Oil Dielectric Loss in Power Transformers
In the process of power operation,the high loss factor of transformer oil medium is a common problem,and solving this problem is of great significance for the stable and effective operation of transformers.The article explores the problem of oil medium loss in a 110 kV transformer of a power plant,analyzes the reasons for the high oil medium loss factor,and proposes countermeasures such as heating transformer oil,adsorbing impurities,and replacing transformer oil.