摘要

感应耐压试验是一种比较可靠的测试变压器纵绝缘性能的方法.通过感应耐压试验能有效检验变压器的绝缘状态.文章论述了电力变压器感应耐压试验的原理,结合实例对感应耐压试验方法、关键试验设备的选择和参数确定进行分析.

Abstract

Induction voltage withstand test is a reliable method to test the longitudinal insulation performance of transformer.The insulation state of transformer can be checked effectively by induction voltage test.This paper discusses the principle of induction withstand voltage test of power transformer,and analyzes the induction withstand voltage test method,the selection of key test equipment and the determination of parameters.

关键词

变压器/感应耐压试验/参数/设备

Key words

transformer/induced voltage withstand test/parameters/equipment