Optimization of Axial Vent of Stator of Water-cooled Motor Based on Multi-physical Field
The numerical simulation analysis was used to conduct simulation and comparison calculations for two different stator yoke axial vent positions in electromagnetic,structural,and ther-mal flow multi-physical field.It focus on studying the impact of vent position on electromagnetic loss,motor structural modal vibration modes,natural frequencies,and temperature differences of components.The simulation helps to understand the mechanism and characteristics of heat exchange in water-cooled motor,providing data support for the subsequent design and optimization.
axial ventelectromagnetic lossnatural frequencytemperature distribution