首页|基于NIR-TDLAS的香烟燃烧过程氰化氢测量

基于NIR-TDLAS的香烟燃烧过程氰化氢测量

扫码查看
氰化氢(HCN)是香烟燃烧过程释放的一种重要产物,严重危害人体健康.然而传统的气相色谱法等方法很难实现燃烧过程中HCN的实时测量.本工作采用中心波长为1.53μm的分布式反馈激光器作为光源,结合激光吸收光谱(TDLAS)技术,对香烟燃烧过程中HCN气体的释放规律进行研究.实验系统采用Herriott型多光程池增加激光的有效光程,反射次数达35次,有效光程达17.5 m;同时利用嵌入式系统对原始解调的吸收信号进行采集与滤波,最终根据测得的光谱信号计算得到HCN浓度;此外,还应用波长调制与解调光谱技术提高系统的检测灵敏度与稳定性.校准实验表明,在0.001%~0.01%浓度范围内,HCN的决定系数R2为0.9974.利用该系统对0.002%标准HCN气体进行1000 s的连续监测,Allan方差分析表明,在55 s的积分时间内,系统的理论检测极限达到22×10-9,验证了检测系统的稳定性.为研究不同吸烟条件下香烟HCN的变化规律,实验模拟了100 ml/min到400 ml/min不同的采样流速和17%、22%、30%、40%等氧气氛围下香烟燃烧释放的HCN浓度.结果表明,单位时间内香烟燃烧过程释放的HCN浓度与采样流速和氧气浓度正相关,而整个燃烧过程中释放的HCN总量与氧气浓度负相关.本工作的开展为进一步研究香烟燃烧过程中的HCN的生成机理提供了基础,同时也为在近红外波段实现烟气中HCN以及其他痕量气体的测量提供了一种有效借鉴.
Measurement of hydrogen cyanide during cigarette combustion process based on NIR-TDLAS
Hydrogen cyanide (HCN) is an important product released during cigarette combustion,which seriously endangers human health. However,traditional methods such as gas chromatography are difficult to achieve real-time measurements during the combustion process. In this work,the evolution of released HCN during cigarette combustion is researched by employing laser absorption spectroscopy (TDLAS) technique,where a distributed feedback laser with a central wavelength of 1.53 μm is selected as the light source. In the experimental system,a Herriott multi-path cell is used to increase the effective optical path of the laser,with 35 reflections and 17.5 m effective optical path,At the same time,the embedded system is used to collect and filter the absorption signal of the original demodulation,and finally the HCN concentration is calculated according to the measured spectral signal. In addition,wavelength modulation and demodulation spectroscopy are applied to improve the detection sensitivity and stability of the system. Calibration experiments show that the determination coefficient R2 of HCN is 0.9974 in the concentration range of 0.001%-0.01%. The system continuously monitors 0.002% standard HCN gas for 1000 s,and Allan variance analysis shows that the theoretical detection limit of the system reaches 22 × 10-9 within 55 s integration time,verifying the stability of the detection system. In order to study the evolution of HCN produced under different smoking conditions,experiments are conducted to simulate the release of HCN from cigarette combustion under different sampling flow rates from 100 ml/min to 400 ml/min and oxygen atmosphere of 17%,22%,30% and 40%. The results show that the HCN concentration released during cigarette combustion per unit time is positively correlated with sampling flow rate and oxygen concentration,while the total amount of HCN released during the entire combustion process is negatively correlated with oxygen concentration. This work provides a basis for further research on the generation mechanism of cigarettes are burned to produce HCN. And also provides an effective reference for the measurement of HCN and other trace gases in smoke in the near-infrared band.

hydrogen cyanidelaser absorption spectrumcigarette burnAllan variance

马晋、段政、朱宏历、郭古青、宫廷、孙小聪、李传亮、邱选兵

展开 >

太原科技大学应用科学学院物理系,山西省精密测量与在线检测装备工程研究中心,山西太原 030024

氰化氢 激光吸收光谱 香烟燃烧 Allan方差

2024

大气与环境光学学报
中国科学院安徽光学精密机械研究所

大气与环境光学学报

影响因子:0.285
ISSN:1673-6141
年,卷(期):2024.19(5)