首页|PV-VSG光伏电站一次调频试验及性能评估方法研究与应用

PV-VSG光伏电站一次调频试验及性能评估方法研究与应用

扫码查看
光伏发电的随机性导致了不同光伏电站出现一次调频性能不足、接入电网频率失稳等问题.而光伏场站的一次调频能力是维持电网稳定性的关键,因此对光伏电站的一次调频能力进行测试与评估具有重要意义.以石城子某光伏电站机组为例,详细介绍了PV-VSG光伏电站实施一次调频的意义、原理及措施,并提出了适用于该光伏电站的一次调频试验技术方案和试验方法.通过频率阶跃及模拟实际电网频率扰动、防扰动性能及自动发电控制(Automatic generation control,AGC)协调的合格率对光伏电站的安全性及稳定性进行评估,具有实际应用价值和推广意义.
Research and Application of Primary Frequency Modulation Test and Performance Evaluation Method for PV-VSG Photovoltaic Power Station
Considering the randomness of photovoltaic(PV) power generation,issues such as insufficient primary frequency modulation(FM) performance and grid frequency instability occur in different PV power stations.And the primary FM capability of PV station is the key to maintain grid stability,so it is of great significance to test and evaluate the primary frequency regulation capability of PV power plant.Taking an example of a PV-VSG photovoltaic power plant unit in Shichengzi,the significance,principle and measures of the implementation of primary FM in power station are introduced in detail,and a primary FM test technical scheme and experimental method suitable for the PV power station is proposed.Evaluation of PV plant security and stability is done by the disturbances of frequency step and simulation of actual grid frequency,calibration pass rates of anti-disturbance performance and AGC coordination,and it has practical application value and promotional significance.

Photovoltaic power generationprimary frequency regulationexperimental studyfrequency step perturbation

黄俊梅、廖作杰、陈建新、李鹏涛

展开 >

陕西能源职业技术学院智能制造与信息工程学院 咸阳 712000

中国石油集团川庆钻探工程有限公司长庆井下技术作业公司 西安 710072

西北工业大学超常条件材料物理与化学教育部重点实验室 西安 710072

西安理工大学材料科学与工程学院 西安 710072

展开 >

光伏发电 一次调频 试验研究 频率阶跃扰动

国家自然科学基金陕西能源职业技术学院低碳清洁能源与智能制造科研创新团队陕西省科技计划

519011842021KYTD062024JC-YBMS-409

2024

电气工程学报
机械工业信息研究院

电气工程学报

CSTPCD北大核心
影响因子:0.121
ISSN:2095-9524
年,卷(期):2024.19(2)
  • 17