BEARING CAPACITY EVALUATION METHODS OF STEEL STRUCTURE BUILDINGS
To properly assess the safety of the steel structure,the entire structure's foundation bearing capacity is calculated,and the bending bearing capacity of H-shaped steel beams and columns is simulated using ABAQUS. The maximum stress ratio of the entire structure is then determined based on these finite element results,indicating a positive correlation between the area of the structure section and its bearing capacity. A larger bearing capacity en-sures greater security and stability. The bending capacity of H-shaped steel beams initially decreases and then in-creases with increasing weld strength,and the critical weld strength is around 350MPa. The maximum stress ratio of the H-shaped steel roof truss is 1.00,the minimum stress ratio is 0.03,the maximum internal stress of the steel beam is approximately 58.2%of the ultimate stress. Finally,the method provides a dependable basis for calculating steel structure's bearing capacity.
structural reliabilityflexural capacityfinite element modelweld strength