变压器中性点接地的模式分析
Analysis of Neutral Grounding Mode for Transformers
张绍荣1
作者信息
- 1. 中铁建设集团有限公司,北京 100040
- 折叠
摘要
阐述基于变电系统案例的变压器低压侧中性点接地设计与施工要点,探讨使用PE线接地时的关键技术,包括变电所内PE线的设置、接地电阻的设计、灵活的接地方式.
Abstract
This paper expounds the design and construction points of neutral grounding on the low-voltage side of transformers based on a case study of a substation system.It explores the key technologies for using PE wire grounding,including the setting of PE wire in the substation,the design of grounding resistance,and flexible grounding methods.
关键词
变电系统/系统接地/保护接地/中性点接地Key words
substation system/system grounding/protective grounding/neutral point grounding引用本文复制引用
出版年