首页|改进双谱自适应功率调节算法的HPLC信道监测

改进双谱自适应功率调节算法的HPLC信道监测

扫码查看
宽带电力线载波通信HPLC信道容易受到非高斯白噪声信号影响,导致信道监测结果不精准.为此,提出了改进双谱自适应功率调节算法的HPLC信道监测方法.分析HPLC信道信号传输特性,构建信号衰落传递函数.采用改进双谱自适应功率调节算法,输出调节累积量结果,通过自回归调节时间序列傅里叶变换,获取双谱处理信号.采用周期性/睡眠监测机制,根据HPLC信道分类函数,实现HPLC信道监测.由实验结果可知,该方法在正常通信环境下获取的信道电压信号波动与实际输出的时域波形一致,在异常通信环境下信道电压信号波动只在部分时间段存在最大为20V的波动误差,其余时间段与实际时域波形一致.
Improved bispectral adaptive power regulation algorithm for HPLC channel monitoring
The HPLC channel of wideband power line carrier communication is easily affected by non-Gaussian white noise signal,which leads to inaccurate channel monitoring results.Therefore,a HPLC channel monitoring method with improved bispectral adaptive power regulation algorithm is proposed.The signal transmission characteristics of HPLC channel were analyzed,and the signal fading transfer function was constructed.The improved bispectral adaptive power regulation algorithm is used to output the adjusting cumulant results,and the time series Fourier transform is adjusted by autoregression to obtain the bispectral processing signal.Periodic/sleep monitoring mechanism was used to realize HPLC channel monitoring according to HPLC channel classification function.The experimental results show that the channel voltage signal fluctuation obtained by this method is consistent with the actual output time-domain waveform in normal communication environment,while the channel voltage signal fluctuation error of the maximum 20 V in some time periods in abnormal communication environment is consistent with the actual time-domain waveform in other time periods.

improving bispectral adaptive power regulationHPLC channelsignal attenuationchannel classification function

闫润珍、苏蕊、温金梅

展开 >

国网甘肃省电力公司数字化事业部,甘肃 兰州 730000

改进双谱自适应功率调节 HPLC信道 信号衰减 信道分类函数

2025

电子设计工程
西安三才科技实业有限公司

电子设计工程

影响因子:0.333
ISSN:1674-6236
年,卷(期):2025.33(3)