通过管子弯头的应力增强系数相等、管子抗弯刚度相等和管子质量相等来对管道进行当量管计算.使用CAESAR Ⅱ 2014管道分析软件进行模拟计算,来验证当量管组计算的可行性.通过计算,当量管组与真实管组管道应力计算的偏差不到3%,当量管组完全满足工程应用.
The equivalent tube calculation is performed on the pipeline by the equal stress intensity factor of the pipe el-bow,the equal bending stiffness of the pipe and the equal mass of the pipe.The CAESAR 11 2014 pipeline analysis soft-ware was used for simulation calculations to verify the feasibility of the equivalent tube calculation.Through calculation,the deviation between the equivalent tube and the actual tube stress calculation is less than 3%.The equivalent tube fully meets the engineering application.