电站系统工程2024,Vol.40Issue(5) :81-82,84.

当量管计算研究

Equivalent Tube Calculation Study

龙志云 肖琦 王慧文 胡双男
电站系统工程2024,Vol.40Issue(5) :81-82,84.

当量管计算研究

Equivalent Tube Calculation Study

龙志云 1肖琦 1王慧文 1胡双男1
扫码查看

作者信息

  • 1. 哈尔滨锅炉厂有限责任公司
  • 折叠

摘要

通过管子弯头的应力增强系数相等、管子抗弯刚度相等和管子质量相等来对管道进行当量管计算.使用CAESAR Ⅱ 2014管道分析软件进行模拟计算,来验证当量管组计算的可行性.通过计算,当量管组与真实管组管道应力计算的偏差不到3%,当量管组完全满足工程应用.

Abstract

The equivalent tube calculation is performed on the pipeline by the equal stress intensity factor of the pipe el-bow,the equal bending stiffness of the pipe and the equal mass of the pipe.The CAESAR 11 2014 pipeline analysis soft-ware was used for simulation calculations to verify the feasibility of the equivalent tube calculation.Through calculation,the deviation between the equivalent tube and the actual tube stress calculation is less than 3%.The equivalent tube fully meets the engineering application.

关键词

当量管/应力计算/数值模拟

Key words

equivalent tube/stress calculation/numerical simulation