首页|基于光伏发电模型的低成本状态监测方法的应用

基于光伏发电模型的低成本状态监测方法的应用

扫码查看
通过与多种监测方法进行对比,合理地构建光伏发电模型,将实际单位面积光伏发电量与模型单位面积光伏发电量进行比较,验证是否可以通过所建立的光伏发电模型低成本实现对光伏发电设备的状态监测.在首次实践中,直观地从状态监测结果发现了存在异常的光伏发电设备.通过分析处理,解决了热斑导致的组串故障,组串接入不合理导致的功率受限,以及冷凝云雾遮挡导致的异常波动,最终证实了方法的低成本和有效性.
Application of Low Cost Status Monitoring Method Based on Photovoltaic Power Generation Model
A photovoltaic power generation model was reasonably established through comparing with several monitoring methods,and comparisons were conducted between the photovoltaic power generation per unit area of actual equipment and model,so as to verify whether the established photovoltaic power generation model can realize the status monitoring of photovoltaic power generation equipment with low cost.The abnormal photovoltaic power generation equipment is visually detected from the status monitoring results in the first practical application.Following problems have been solved during analysing and treatment process,such as the string fault caused by hot spots,power limitation caused by unreasonable string connection,and abnormal fluctuation caused by condensation cloud covering.Finally,it is confirmed that this method could indeed be implemented with low cost and demonstrate a certain level of effectiveness.

photovoltaic plantpower generation modelstatus monitoringlow costeffectiveness

雷顶、耿旭宁、金中豪、唐彬

展开 >

上海漕泾热电有限责任公司,上海 201507

光伏电站 发电模型 状态监测 低成本 有效性

2025

发电设备
上海发电设备成套设计研究院

发电设备

影响因子:0.26
ISSN:1671-086X
年,卷(期):2025.39(1)