腹腔镜外科杂志2024,Vol.29Issue(1) :48-51.DOI:10.13499/j.cnki.fqjwkzz.2024.01.048

无褶皱吻合技术治疗结直肠恶性梗阻的应用价值

The clinical value of modified foldless anastomosis in the treatment of malignant colorectal obstruction

王娟 武广海 张帅 李超 徐靖
腹腔镜外科杂志2024,Vol.29Issue(1) :48-51.DOI:10.13499/j.cnki.fqjwkzz.2024.01.048

无褶皱吻合技术治疗结直肠恶性梗阻的应用价值

The clinical value of modified foldless anastomosis in the treatment of malignant colorectal obstruction

王娟 1武广海 1张帅 1李超 1徐靖1
扫码查看

作者信息

  • 1. 天津市人民医院天津市普通外科学重点建设学科实验室 天津市人民医院普通外科,天津,300121
  • 折叠

摘要

目的:探讨结直肠吻合新技术无褶皱吻合术治疗结直肠恶性梗阻的应用价值.方法:收集 2020 年 1 月至 2022年12 月收治的54 例左半结肠直肠癌合并结直肠梗阻患者的临床资料.患者均为急诊就诊,确诊结直肠梗阻且腹部CT测量扩张肠管直径>30 mm.急症行内镜下经肛肠道自膨式金属支架置入术,术中取活检,病理结果证实恶性肿瘤.限期行腹腔镜结直肠癌切除术,术中应用无褶皱吻合技术进行一期吻合.术后随访 7~24 个月,评估吻合口相关并发症情况.结果:54 例均完成腹腔镜结直肠癌切除术.术中测量近端肠管直径 29.50~45.80 mm,平均(36.29±4.51)mm;远端肠管直径 19.50~32.60 mm,平均(24.93±4.19)mm.近远端肠管管径不一致,行无褶皱吻合术,吻合放置抵钉座时间 3~5 min,平均(3.80±0.79)min.术后无吻合口出血、狭窄、漏等并发症发生,术后随访未发生局部复发等远期并发症.结论:无褶皱吻合技术应用于结直肠恶性梗阻支架置入术后吻合确切,手术安全、可靠.

Abstract

Objective:To introduce a new technique of foldless anastomosis and evaluate its effect in the treatment of malignant colorectal obstruction.Methods:Clinical data were collected from 54 patients with left colorectal cancer complicated with colorectal obstruction from Jan.2020 to Dec.2022.All patients were diagnosed as colorectal obstruction with dilated intestine in the emergency department,and the diameter of the dilated intestinal lumen was more than 30 mm measured by abdominal CT.Emergency endoscopic transanal self-expanding metallic stent placement was performed for all enrolled patients.During the operation,biopsy was taken to con-firm malignant tumor through pathology.Laparoscopic resection of colorectal cancer was performed within a limited time,utilizing the foldless anastomosis technique for one-stage anastomosis.Anastomotic complications were evaluated through a follow-up period of 7-24 months.Results:All 54 patients successfully underwent laparoscopic resection of colorectal cancer.According to the measured data during the operation,the proximal bowel diameter ranged from29.50 to45.80 mm,with a mean of(36.29±4.51)mm,while the distal bowel diameter ranging from19.50 to32.60 mm,with a mean of(24.93±4.19)mm.The diameters of proximal and distal intestinal canal were inconsistent.Foldless anastomosis was performed,the anvil placement time ranged from3 to5 min,with an average of(3.80±0.79)min.No postoperative complications such as anastomotic bleeding,stenosis,anastomotic leakage occurred,and there were no long-term complications of local recurrence during the follow-up period.Conclusions:The foldless anastomosis is a safe and reliable tech-nique that has exact anastomosis effect in patients with malignant colorectal obstruction after stent implantation.

关键词

结直肠肿瘤/肠梗阻/腹腔镜检查/无褶皱吻合/自膨式金属支架

Key words

Colorectal neoplasms/Intestinal obstruction/Laparoscopy/Foldless anastomosis/Self-expanding metal bracket

引用本文复制引用

基金项目

天津市医学重点学科(专科)建设项目(TJYXZDXK-058B)

天津市自然科学基金(21JCYBJC01070)

北京科创医学发展基金(KC2021-JX-0186-93)

天津市人民医院院内课题(2020YJ003)

出版年

2024
腹腔镜外科杂志
山东大学

腹腔镜外科杂志

CSTPCD
影响因子:0.861
ISSN:1009-6612
参考文献量21
段落导航相关论文