腐蚀与防护2024,Vol.45Issue(2) :90-96.DOI:10.11973/fsyfh-202402013

动态杂散电流干扰下管地电位的波动特征

Fluctuation Characteristics of Pipe-to-Soil Potential under Dynamic Stray Current Interference

马帅杰 冯志永 杜艳霞 陈乐
腐蚀与防护2024,Vol.45Issue(2) :90-96.DOI:10.11973/fsyfh-202402013

动态杂散电流干扰下管地电位的波动特征

Fluctuation Characteristics of Pipe-to-Soil Potential under Dynamic Stray Current Interference

马帅杰 1冯志永 2杜艳霞 3陈乐3
扫码查看

作者信息

  • 1. 北京科技大学新材料技术研究院,北京 100083;郑州机械研究所有限公司新型钎焊材料与技术国家重点实验室,郑州 450001
  • 2. 北京市燃气集团有限责任公司,北京 100035
  • 3. 北京科技大学新材料技术研究院,北京 100083
  • 折叠

摘要

在地铁、高铁和高压直流(HVDC)输电系统接地极双极运行引起的动态杂散电流干扰下,现场监测得到196组管地电位数据.在时域上分析了不同干扰下管地电位的动态波动特征,然后利用信号学上连续小波变换(CWT)的方法在频域上研究了不同干扰下管地电位的动态波动特性,统计了不同干扰下管地电位的周期分布范围,并对比了其周期分布的差异.结果表明:三种干扰源都对管道造成动态直流干扰,其中地铁和高铁干扰呈现白天干扰严重、夜间平稳的周期性变化,而HVDC干扰则与高压直流输电系统接地极入地电流的大小与方向有关,没有明显的昼夜差别;高铁交流干扰同时伴随着显著的直流干扰;地铁直流干扰的周期占比随周期增大呈现先增大后减小的趋势,因高铁线路不同,管道干扰的周期分布也有所不同,但主要分布在大于500 s的范围,HVDC干扰引起的管地直流电位波动周期分布较为均匀.

Abstract

196 sets of data on pipe-to-soil potential of pipeline under dynamic stray current interference caused by metro,high-speed railway and high voltage direct current(HVDC)transmission system grounding bipolar operation were obtained through field monitoring.The dynamic fluctuation characteristics of pipe-to-soil potential under different interference were analyzed in time domain first,and then in frequency domain by means of continuous wavelet transform(CWT).The periodic distribution ranges of pipe-to-soil potential under different interference were calculated,and the difference of their periodic distribution was compared.The results show that the three interference sources all caused dynamic DC interference to the pipeline.The interference from metro and high-speed railway presented a periodic change of serious during the day and the stable at night,while the interference from HVDC was related to the intensity and direction of the current from grounding electrode in high-voltage transmission line and had no obvious difference between day and night.The AC interference of high-speed railway was accompanied by significant DC interference.The period proportion of metro DC interference increased first and then decreased with the increase of the period.The period distribution of interference to pipeline changed with high-speed railway line,but it was mainly in the range of greater than 500 s.The potential fluctuation period of pipe-to-soil DC caused by HVDC interference was evenly distributed.

关键词

动态杂散电流/管地电位/现场数据/连续小波变换(CWT)/波动周期

Key words

dynamic stray current/pipe-to-soil potential/field data/continuous wavelet transform(CWT)/period of fluctuation

引用本文复制引用

出版年

2024
腐蚀与防护
上海市腐蚀科学技术学会 上海材料研究所

腐蚀与防护

CSTPCD北大核心
影响因子:0.462
ISSN:1005-748X
参考文献量12
段落导航相关论文