腐蚀与防护2024,Vol.45Issue(6) :119-125.DOI:10.11973/fsyfh-202406018

某核电厂蒸汽发生器排污净化系统泵出口管道泄漏原因

Leakage Causes of Pump Outlet Pipes of Steam Generator Sewage Purification System in a Nuclear Power Plant

韩辉 许新竹
腐蚀与防护2024,Vol.45Issue(6) :119-125.DOI:10.11973/fsyfh-202406018

某核电厂蒸汽发生器排污净化系统泵出口管道泄漏原因

Leakage Causes of Pump Outlet Pipes of Steam Generator Sewage Purification System in a Nuclear Power Plant

韩辉 1许新竹1
扫码查看

作者信息

  • 1. 江苏核电有限公司,连云港 222042
  • 折叠

摘要

国内某机组运行 15 a后,蒸汽发生器排污净化系统泵出口管道发生泄漏.采用超声波测厚、化学成分分析、金相检验、扫描电镜观察、能谱分析及流场模拟计算等方法,分析了管道泄漏的原因.结果表明:低温流动加速腐蚀(FAC)导致管壁减薄,最终导致管道泄漏,管件材质、几何形状,介质pH、温度、溶解氧含量及流速等是发生FAC的重要因素.

Abstract

After 15 years of operation of a domestic nuclear power plant,the outlet of the pump of the steam generator sewage purification system leaked.The reasons for the leaking of pipe were analyzed by composition analysis,metallographic inspection,scanning electron microscope observation,energy spectrum analysis and flow field simulation calculation.The results show that the thinning of the pipe wall was caused by flow accelerated corrosion(FAC)with low temperature,eventually leading to the leakage.The pipe material,geometry,pH value of the medium,temperature,dissolved oxygen content and flow rate were important factors for the FAC.

关键词

管道/泄漏/流动加速腐蚀(FAC)/温度/介质

Key words

pipe/leakage/flow accelerated corrosion(FAC)/temperature/medium

引用本文复制引用

出版年

2024
腐蚀与防护
上海市腐蚀科学技术学会 上海材料研究所

腐蚀与防护

CSTPCDCSCD北大核心
影响因子:0.462
ISSN:1005-748X
参考文献量11
段落导航相关论文